top of page
Technical Specifications
• Drive: Electronic
• Frequency: from 5 to 40 BPM
• Alarms:
- High pressure
- Low pressure
- Apnea
- Pneumatic supply
- Low battery
• Flow: 2 to 20 l/min
• I/E Ratio: 1:2
• Oxygen concentration: 60% or 100% Patented system
• Trigger: from -12 to -2 mbar
• Overpressure valve: 20-60 cm H2O - adjustable
• Battery operating time: Approx. 3 hours
• Manometer scale: -20 to +80 mbar
• IP protection: IP24
• Non re-breathing valve: 60 cm H2O
• Pneumatic supply: from 280 to 600 kPa
• Pneumatic connection: UNI
• External source: 12 V DC (on request AC/DC adapter 100-240 V, 50/60 Hz)
• Internal source: Rechargeable Ni-Mh battery
• Dimensions: 330x177x210 mm
• Weight: 3.6 kg
• Structure: Aluminium, steel, brass, PE
Standard accessories
• Patient circuit (corrugated tubing with non re-breathing valve)
• Power cable
• Oxygen tube
• Manual: GB, IT, on request FR, ES, DE, PT
• Adult face-mask
• Battery
• UNI adaptor

SPENCER ELECTRONIC VENTILATOR 190

SKU: 34009
€9,570.00Price
Quantity
  • SPENCER 190 NXT ELECTRONIC VENTILATOR

    Electronic lung ventilators for non invasive ventilation of adult and pediatric patients

    - protection against accidental activation of the AIR mix selection lever
    - colour coded manometer for easy identification of pressure ranges
    - positioning of input and output ports on the side of the device, make connecting and disconnecting easier and offer greater protection to the elements connected to the device
    - control knobs on high contrast background for a better identification of the set values
    - compact, lightweight aluminium frame
    - place and shape of adjustment knobs make the setting of parameters easier in all operative conditions
    - constant I/E ratio
    - alarms for ventilation monitoring and device management

    Ventilator 190 NXT features:
    - led bar for breath monitoring
    - three ventilation modes (only one for 34006-7)
    - CMV: mandatory inflation is initiated according to the set parameters
    - TVM: inflation initiated according to the set parameters only if triggered by the patient
    - A/CV: inflation is assured to be initiated at intervals determined by the set rate, unless initiated by an earlier patient trigger event.

    Made in Italy.

medical_biology_detail_medicine_psychedelic_science_abstract_abstraction_chemistry_Genetic

Get in Touch with us

Lorem Ipsum is simply dummy

Call Us

+32469418650

Address

Emile Moysonlann 9000 Gent/Belgium

We delivering innovative solutions that drive sustainable growth and success for you

  • Whatsapp
  • Telegram
  • Facebook
  • LinkedIn
  • X
  • Instagram

Products

Diagnostic equipment

Surgical Instruments

Patient care equipment

Home Care Products

Accessories and Consumables

Our Newsletter

Copyright 2025 - All Rights Reserved By Medical equipment Land

Trams & Condition   Privacy Policy

bottom of page