| Technical Specifications | General • Dimensions/Weight: 238x163xh 250 mm/4 kg • Trace: 6 waveform (ECGx2, SpO2, RR or EtCO2 IBPx2) • Indicators: categorized alarms (3 priority levels), visual alarm lamp handle, QRS beep, SpO2 pulse beep, heart rate, SpO2 pulse pitch tone battery status, external power LED • Thermal printer: 25, 50 mm/sec (paper width 58 mm) • Battery: Rechargeable Li-ion (3 hours operating time) • Interfaces: LAN digital output for transferring data Nurse call system connection defibrillator sync. output • DC input connector:18 VDC, 2.8A max • Operating voltage: 100-240 V, 50-60 Hz
SpO2 • % Saturation Range: 0% to 100% ±2 digits (70 to 100%) • Pulse Rate Range: 30 to 254 bpm ±2 bpm
ECG • Lead type: 3-lead, 5-lead • Lead selection: 3-lead: I, II, III • ECG Waveforms: 3-lead 1 channel 5-lead: 1/2/7 channels • Heart rate range: Adult: 30-300 bpm Neonate/pediatric: 30-350 bpm • Heart rate accuracy: ± 1 bpm or ± 1%, wichever is greater • Sweep speed: 6.25, 12.5, 25, 50 mm/sec. • Filter: Diagnoses: 0.05 to 150 Hz Monitoring 0.5 to 40 Hz Moderate: 0.5 to 25 Hz Maximum: 5 to 25 Hz • S-T Segment detection range: - 2.0 to 2.0 mV • Arrhythmia analysis: Asystole, Vtach, Vfib, Bigeminy, Accvent Couplet, Irregular, Pause, Pvc, Ront, Trigeminy, Vbrady, Shortrun • Pacemaker detection mode: Indicator on waveform display (user selectable) • Protecion: against electrosurgical interference and defibrillation
NIBP • Technique: Oscillometric with linear deflation • Pressure range: 0 to 300 mmHg ± 3 mmHg • Measurement Modes: Manual-Automatic-Continuous • Safety pressure: Adult: 300 mmHg Neonate: 150 mmHg • Measurement range: Adult pressure: 20 to 260 mmHg Pediatric pressure: 20 to 160 mmHg Neonate pressure: 20 to 130 mmHg Pulse rate: 30-220 bpm • Accuracy: meets accuracy requirements of ANSI/AAMI ISO 81060-2-2013
Respirations • Range: 5 to 120 breaths/min ±1 b/min • Apnea alarm: yes
Temperature Unit • Range: 0° to 50°C (32°F to 122°F) • Accuracy: ± 0.1°C (25 to 50°C), ± 0.2°C (0 to 24°C) • Compatible with: YSI Series 400 Temperature Probes
IBP - option • Channels: 2 • Measuring range: -50 to 300 mmHg • Measuring accuracy: ± 1 mmHg (<100 mmHg) ± 1 % of reading(>100 mmHg) • Pulse rate counting range: 0 to 300 beats/min • Zero balancing: range ± 200 mmHg accuracy ± 1 mmHg drift ± 1 mmHg over 24 hours • Transducer sensitivity: 5µV/V mmHg
EtCO2 - Respironics option • Measurement mode: Sidestream or Mainstream • Measurement range: 0~150 mmHg, 0 to 19% • Respiration range: 2~150 bpm • Accuracy: ± 2 mmHg, 0~40 mmHg ± 5%, 41~70 mmHg ± 8%, 71~100 mmHg ± 10%, 101~150 mmHg • Respiration accuracy: ± 1 breath per minute |
|