top of page
Technical Specifications
• Minimum preselectable power: 0
• Level step: 1
• Maximum output power CUT (W): 120 250 Ohm
• Maximum output power BLEND (W): 90 200 Ohm
• Maximum output power COAG FORCED (W): 80 150 Ohm
• Maximum output power COAG SOFT (W): 60 100 Ohm
• Maximum output power BIPOLAR (W): 40 100 Ohm
• Working frequency: 600 kHz
• Weight kg: 7
• Size LxHxD mm: 260 x 110 x 265
• Operating voltage (switchable): 115 -230
• Mains frequency (Hz): 50-60
• Fuses 230Vac (5x20) TIMED: 2 x 3,15A
• Fuses 115Vac (5x20) TIMED: 2 x 6,3A
• Electrical input power (VA): 300
• Electrical input current (230 Vac) (A): 1,3
• Electrical input current (115 Vac) (A): 2,6
• Five steps adjustable sound level (from 55- to 75dBA): YES
• Self-check: YES
• Power accuracy output warning: YES
• Split or not split patient plate allowed: YES
• Last working condition storing: YES
• Electrical Class (EN60601 - 1): I CF
• MDD 93/42/EEC Class: II B
• Patient circuit: F
Standard accessories
• MB single-use two button handle
• MB operative foot-switch 30577 (usable as alternative to handle)
• MB fl at neutral plate with cable 30564
• Kit of 6 short autoclavable electrodes, diam. 2.4 mm
• User manual: available in GB, ES, IT, FR, PL.
• Power cable 2 m

DIATERMO MB 122 - mono-bipolar - 120 Watt

SKU: 30540
€1,732.00Price
Quantity
  • DIATERMO MB 122 - mono-bipolar - 120 W

    MB 122 is an HF electrosurgical unit suitable to perform middle monopolar or bipolar electrosurgery.

    By selection of the modes of operation they provide pure cut, coagulated cut, forced coagulation, soft coagulation and, with forceps, bipolar coagulation.

    The use of either split or normal neutral plate is allowed.

    Leading-Edge Technology: this advanced concept device enables highly professional surgery intervention thanks to ergonomic and safety features derived from high power theatre apparatus.

    Complete safety: open Circuit (OC) Alarm warns the user that connection into the neutral plate has not been made or that the cable is disconnected or the neutral plate is not in contact with the patient.

    The alarm is signaled by an intermittent beep together with a flashing red light on the front panel. In this case HF emission for cut and coagulation operation is switched off.

    OVT Alarm: the unit includes an internal circuit protection warning when the current delivery is exceeding.

    Made in Italy.

medical_biology_detail_medicine_psychedelic_science_abstract_abstraction_chemistry_Genetic

Get in Touch with us

Lorem Ipsum is simply dummy

Call Us

+32469418650

Address

Emile Moysonlann 9000 Gent/Belgium

We delivering innovative solutions that drive sustainable growth and success for you

  • Whatsapp
  • Telegram
  • Facebook
  • LinkedIn
  • X
  • Instagram

Products

Diagnostic equipment

Surgical Instruments

Patient care equipment

Home Care Products

Accessories and Consumables

Our Newsletter

Copyright 2025 - All Rights Reserved By Medical equipment Land

Trams & Condition   Privacy Policy

bottom of page